Overview
Laser tubes and sources need a constant water temperature to keep power output and beam quality stable. Our laser chillers hold the set point with a stainless-steel evaporator and tank, flow switch and full protection package.
Sizes from 0.5 HP (single compressor) to 30 HP (dual compressor) cover everything from small engravers to large laser cutting lines used for shoe uppers.
Applications
- Laser cutting and marking machines for uppers
- CNC spindles
- Ultrasonic and welding equipment
Key features
- Compact, quiet design: high-efficiency heat-transfer tubes with an imported hermetic scroll compressor, small, light and low-vibration, typically 20–30% more efficient than piston compressors.
- Load-following energy control: the microcomputer compares actual load with the set point and adjusts output in real time, keeping efficiency high at part load.
- Simple operation: microcomputer controller with digital display shows all operating values; temperature control accuracy ±1 °C (±0.1 °C on request), range 5–50 °C.
- Full protection: compressor over-current, pump over-current, low chilled-water flow, low leaving-water temperature, over-temperature, overload, anti-short-cycle, voltage abnormality and high/low pressure protection.
- Multiple independent safety circuits in addition to the compressor’s own protection module.
- Air-cooled models need no cooling tower or tower pump and are easy to move.
- Factory assembled, run-tested and charged with refrigerant and oil, connect water and power and start.
Technical data
Available in 15 configurations. Scroll sideways on small screens to see every column.
| Parameter | Unit | 0.5 HP | 1 HP | 1.5 HP | 2 HP | 3 HP | 4 HP | 5 HP | 6 HP | 8 HP (2 comp.) | 10 HP (2 comp.) | 12 HP (2 comp.) | 15 HP (2 comp.) | 20 HP (2 comp.) | 25 HP (2 comp.) | 30 HP (2 comp.) |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Cooling capacity, 50 Hz | kW | 1.5 | 2.85 | 3.7 | 5.62 | 8.35 | 10.8 | 13.94 | 16.9 | 21.6 | 27.9 | 33.8 | 44.5 | 58.1 | 68 | 86.9 |
| Cooling capacity, 60 Hz | kW | 1.8 | 3.42 | 4.4 | 6.74 | 10.02 | 12.96 | 16.73 | 20.28 | 25.92 | 33.48 | 40.56 | 53.4 | 69.72 | 81.6 | 104.28 |
| Cooling capacity, 50 Hz | kcal/h | 1290 | 2451 | 3182 | 4833 | 7181 | 9288 | 11988 | 14534 | 18576 | 23994 | 29068 | 38270 | 49966 | 58480 | 74734 |
| Total input power | kW | 1.8 | 1.2 | 1.7 | 2 | 2.9 | 3.7 | 4.9 | 5.6 | 7.25 | 10 | 11.4 | 14.6 | 18.8 | 22.6 | 29.1 |
| Max. running current | A | 5.4 | 7.2 | 9 | 13.6 | 7.2 | 9.8 | 12.8 | 15.5 | 20 | 27.9 | 31.3 | 42.4 | 52.7 | 63.7 | 81 |
| Power supply | 1–3 HP: 220/380 V 50/60 Hz · 3 HP and above: 3PH 380/415 V 50/60 Hz (200/220 V on request) | 1–3 HP: 220/380 V 50/60 Hz · 3 HP and above: 3PH 380/415 V 50/60 Hz (200/220 V on request) | 1–3 HP: 220/380 V 50/60 Hz · 3 HP and above: 3PH 380/415 V 50/60 Hz (200/220 V on request) | 1–3 HP: 220/380 V 50/60 Hz · 3 HP and above: 3PH 380/415 V 50/60 Hz (200/220 V on request) | 1–3 HP: 220/380 V 50/60 Hz · 3 HP and above: 3PH 380/415 V 50/60 Hz (200/220 V on request) | 1–3 HP: 220/380 V 50/60 Hz · 3 HP and above: 3PH 380/415 V 50/60 Hz (200/220 V on request) | 1–3 HP: 220/380 V 50/60 Hz · 3 HP and above: 3PH 380/415 V 50/60 Hz (200/220 V on request) | 1–3 HP: 220/380 V 50/60 Hz · 3 HP and above: 3PH 380/415 V 50/60 Hz (200/220 V on request) | 1–3 HP: 220/380 V 50/60 Hz · 3 HP and above: 3PH 380/415 V 50/60 Hz (200/220 V on request) | 1–3 HP: 220/380 V 50/60 Hz · 3 HP and above: 3PH 380/415 V 50/60 Hz (200/220 V on request) | 1–3 HP: 220/380 V 50/60 Hz · 3 HP and above: 3PH 380/415 V 50/60 Hz (200/220 V on request) | 1–3 HP: 220/380 V 50/60 Hz · 3 HP and above: 3PH 380/415 V 50/60 Hz (200/220 V on request) | 1–3 HP: 220/380 V 50/60 Hz · 3 HP and above: 3PH 380/415 V 50/60 Hz (200/220 V on request) | 1–3 HP: 220/380 V 50/60 Hz · 3 HP and above: 3PH 380/415 V 50/60 Hz (200/220 V on request) | 1–3 HP: 220/380 V 50/60 Hz · 3 HP and above: 3PH 380/415 V 50/60 Hz (200/220 V on request) | |
| Refrigerant | R22 / R407C / R134a / R404A / R410A | R22 / R407C / R134a / R404A / R410A | R22 / R407C / R134a / R404A / R410A | R22 / R407C / R134a / R404A / R410A | R22 / R407C / R134a / R404A / R410A | R22 / R407C / R134a / R404A / R410A | R22 / R407C / R134a / R404A / R410A | R22 / R407C / R134a / R404A / R410A | R22 / R407C / R134a / R404A / R410A | R22 / R407C / R134a / R404A / R410A | R22 / R407C / R134a / R404A / R410A | R22 / R407C / R134a / R404A / R410A | R22 / R407C / R134a / R404A / R410A | R22 / R407C / R134a / R404A / R410A | R22 / R407C / R134a / R404A / R410A | |
| Compressor | Hermetic rotary / scroll / piston | Hermetic rotary / scroll / piston | Hermetic rotary / scroll / piston | Hermetic rotary / scroll / piston | Hermetic rotary / scroll / piston | Hermetic rotary / scroll / piston | Hermetic rotary / scroll / piston | Hermetic rotary / scroll / piston | Hermetic rotary / scroll / piston | Hermetic rotary / scroll / piston | Hermetic rotary / scroll / piston | Hermetic rotary / scroll / piston | Hermetic rotary / scroll / piston | Hermetic rotary / scroll / piston | Hermetic rotary / scroll / piston | |
| Compressor power | kW | 0.37 | 0.75 | 1.2 | 1.5 | 2.2 | 3 | 3.8 | 4.5 | 3.0×2 | 3.8×2 | 4.5×2 | 5.6×2 | 7.5×2 | 9.4×2 | 11.3×2 |
| Condenser air flow | m³/h | 750 | 1000 | 1500 | 2000 | 3000 | 4000 | 5000 | 6000 | 8000 | 10000 | 12000 | 15000 | 20000 | 25000 | 30000 |
| Evaporator | Stainless plate / stainless coil in tank | Stainless plate / stainless coil in tank | Stainless plate / stainless coil in tank | Stainless plate / stainless coil in tank | Stainless plate / stainless coil in tank | Stainless plate / stainless coil in tank | Stainless plate / stainless coil in tank | Stainless plate / stainless coil in tank | Stainless plate / stainless coil in tank | Stainless plate / stainless coil in tank | Stainless plate / stainless coil in tank | Stainless plate / stainless coil in tank | Stainless plate / stainless coil in tank | Stainless plate / stainless coil in tank | Stainless plate / stainless coil in tank | |
| Chilled water flow, 50 Hz | m³/h | 0.26 | 0.49 | 0.64 | 0.97 | 1.44 | 1.86 | 2.4 | 2.91 | 3.71 | 4.8 | 5.81 | 7.65 | 10 | 11.69 | 14.94 |
| Water tank | L | 10.6 | 18.3 | 27 | 27 | 50 | 60 | 60 | 110 | 120 | 200 | 200 | 270 | 350 | 350 | 420 |
| Water connection | inch | 1/2 | 1/2 | 1/2 | 1/2 | 1 | 1 | 1 | 1 | 1 | 1-1/2 | 1-1/2 | 1-1/2 | 2 | 2 | 2 |
| Pump power | kW | 0.37 | 0.37 | 0.37 | 0.37 | 0.37 | 0.37 | 0.75 | 0.75 | 0.75 | 1.5 | 1.5 | 2.25 | 2.25 | 2.25 | 3.75 |
| Pump max. head | m | 22 | 22 | 22 | 22 | 22 | 22 | 30 | 30 | 25 | 25 | 25 | 28 | 28 | 28 | 30 |
| Pump max. flow | m³/h | 5.4 | 5.4 | 5.4 | 5.4 | 5.4 | 5.4 | 8.1 | 8.1 | 8.1 | 13.5 | 13.5 | 25.2 | 25.2 | 25.2 | 36 |
| Flow switch | Up to 2 HP: close >3.5 L/min, open <1.4 L/min · 3 HP and above: close >16 L/min, open <10 L/min | Up to 2 HP: close >3.5 L/min, open <1.4 L/min · 3 HP and above: close >16 L/min, open <10 L/min | Up to 2 HP: close >3.5 L/min, open <1.4 L/min · 3 HP and above: close >16 L/min, open <10 L/min | Up to 2 HP: close >3.5 L/min, open <1.4 L/min · 3 HP and above: close >16 L/min, open <10 L/min | Up to 2 HP: close >3.5 L/min, open <1.4 L/min · 3 HP and above: close >16 L/min, open <10 L/min | Up to 2 HP: close >3.5 L/min, open <1.4 L/min · 3 HP and above: close >16 L/min, open <10 L/min | Up to 2 HP: close >3.5 L/min, open <1.4 L/min · 3 HP and above: close >16 L/min, open <10 L/min | Up to 2 HP: close >3.5 L/min, open <1.4 L/min · 3 HP and above: close >16 L/min, open <10 L/min | Up to 2 HP: close >3.5 L/min, open <1.4 L/min · 3 HP and above: close >16 L/min, open <10 L/min | Up to 2 HP: close >3.5 L/min, open <1.4 L/min · 3 HP and above: close >16 L/min, open <10 L/min | Up to 2 HP: close >3.5 L/min, open <1.4 L/min · 3 HP and above: close >16 L/min, open <10 L/min | Up to 2 HP: close >3.5 L/min, open <1.4 L/min · 3 HP and above: close >16 L/min, open <10 L/min | Up to 2 HP: close >3.5 L/min, open <1.4 L/min · 3 HP and above: close >16 L/min, open <10 L/min | Up to 2 HP: close >3.5 L/min, open <1.4 L/min · 3 HP and above: close >16 L/min, open <10 L/min | Up to 2 HP: close >3.5 L/min, open <1.4 L/min · 3 HP and above: close >16 L/min, open <10 L/min | |
| Protection | Compressor overheat, over-current, high/low pressure, pump overpressure, over-temperature, flow, phase sequence/loss, low level, anti-freeze | Compressor overheat, over-current, high/low pressure, pump overpressure, over-temperature, flow, phase sequence/loss, low level, anti-freeze | Compressor overheat, over-current, high/low pressure, pump overpressure, over-temperature, flow, phase sequence/loss, low level, anti-freeze | Compressor overheat, over-current, high/low pressure, pump overpressure, over-temperature, flow, phase sequence/loss, low level, anti-freeze | Compressor overheat, over-current, high/low pressure, pump overpressure, over-temperature, flow, phase sequence/loss, low level, anti-freeze | Compressor overheat, over-current, high/low pressure, pump overpressure, over-temperature, flow, phase sequence/loss, low level, anti-freeze | Compressor overheat, over-current, high/low pressure, pump overpressure, over-temperature, flow, phase sequence/loss, low level, anti-freeze | Compressor overheat, over-current, high/low pressure, pump overpressure, over-temperature, flow, phase sequence/loss, low level, anti-freeze | Compressor overheat, over-current, high/low pressure, pump overpressure, over-temperature, flow, phase sequence/loss, low level, anti-freeze | Compressor overheat, over-current, high/low pressure, pump overpressure, over-temperature, flow, phase sequence/loss, low level, anti-freeze | Compressor overheat, over-current, high/low pressure, pump overpressure, over-temperature, flow, phase sequence/loss, low level, anti-freeze | Compressor overheat, over-current, high/low pressure, pump overpressure, over-temperature, flow, phase sequence/loss, low level, anti-freeze | Compressor overheat, over-current, high/low pressure, pump overpressure, over-temperature, flow, phase sequence/loss, low level, anti-freeze | Compressor overheat, over-current, high/low pressure, pump overpressure, over-temperature, flow, phase sequence/loss, low level, anti-freeze | Compressor overheat, over-current, high/low pressure, pump overpressure, over-temperature, flow, phase sequence/loss, low level, anti-freeze |
Technical data is for reference. Final specifications, voltage (e.g. 380 V / 50 Hz or 440 V / 60 Hz) and options are confirmed in your quotation.
Included with every order
Sourced, inspected and supported.
- Manufacturer audited in person by our team
- Pre-shipment inspection with photo and video report
- Export packing, documents and consolidated shipping
- Optional installation, commissioning and operator training
- Spare parts sourced directly from the manufacturer
Often sourced together

FL-CH-AC
Air-Cooled Industrial Chiller, 3–50 HP
Plug-and-play cooling for moulds and machines, no cooling tower needed.
View specifications
FL-CUT-CNC-1625
CNC Oscillating Knife Leather Cutter with Camera
Digital cutting for leather, synthetics and textiles with camera nesting and defect avoidance, no dies needed.
View specificationsRequest a quote
Get a quote for the Laser Chiller, 0.5–30 HP.
Send a list, a tech pack or just a photo. A sourcing specialist replies within 12 hours with options and landed-cost pricing.